MSE-V60激光測速測長傳感器

所在地: 山東省 煙臺市
發布時間: 2024-12-24
詳細信息


 MSE-V60 Sensor for Speed and Length

 

The non-contact optical MSE-V60 is a modern speed and length  measuring device in a robust aluminum IP65 housing. An automatically controlled white light LED illuminates the surface of the measuring object. The reflected light is projected onto the optical track image sensor by the integrated precision optics. The movement of the measurement object is measured in this way by means of a correlation method. The speed is detected bidirectionally in both the x and y directions.

The MSE-V60 can be used as a direct replacement for measuring wheels or other rotary encoder applications. The built-in TTL incremental output holds two pulse phases for each of the two directions of movement. There is an optionally Ethernet based fieldbus interface available. Thanks to the flexible installation position, the small dimensions and the short working distance of 100 mm, the MSE-V60 can be integrated easily into a wide variety of installations.

Key features

? Acquisition of longitudinal and cross movement

? Detection of moving direction change

? No minimum speed, measurement down to 0 m/s

? No object touch, no slip, non-wearing

? No harmful LASER-light

? Made in Germany

Applications

? Suitable for various cases of applications like cutting, positioning, regulation, inspection, quality control

? Applicable for a wide range of products like strips, webs, plates, tubes, profiles, etc.

? Integrable into winders, slitting lines, coating and inspection lines etc.

Technical Data

Working distance and tolerance

  100 ± 10 mm

Measurement range

0,0 … 300 m/min (0,0 … 5 m/s)

Measurement uncertainty 1)

< 1 %

Reproducibility 1)

< 1 %

Working principle

Correlation

Illumination

White light LED (life span > 5 years, exchangeable)

Supply voltage (Vsup)

12 … 30 V DC

Power consumption

< 7 W

Temperature range

0 °C … 50 °C

Protection level

IP 65

EMC

Conformity according IEC 61326-1:2020

Weight, dimensions

ca. 1,45 kg, 132 mm x 140 mm x 60 mm (without connectors)

Programming interface

USB, for parameter adjustment and software updates

I/O signals

Status output (Vsup- 1 V, 100 mA max., short circuit proof)

Trigger input (10 … 30 V, 3 mA max., opto- isolated)

Incremental output (Encoder)

per direction of movement two phases (A/B, 90°)

5V TTL, output frequency max. 1 MHz, max. 100 mA per phase

Fieldbus interface (optional)

Ethernet (FBFE), Profinet IO (FBPN), Ethernet/IP (FBEI)

Scope of delivery

MSE-V60, data cable, positioning aid, USB memory with documentation and software, printed manual

 

 



聯係方式
返回展廳